What was found
PIT - FOUND FRAME CRACKED TWO PLACES .125 INCH AND .25 INCH, STATION 380 BETWEEN S8R AND S9R. INSTALLED DOUBLER PER SRM 53-00-07. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PIT - FOUND FRAME CRACKED TWO PLACES .125 INCH AND .25 INCH, STATION 380 BETWEEN S8R AND S9R. INSTALLED DOUBLER PER SRM 53-00-07. (M)