What was found
PIT - FOUND FRAME CRACKED .25 INCH, FRAME ATTACH BRACKET HOLE AT STATION 887-S9L. MANUFACTURED REPAIR IAW TYPICAL REPAIR 53-10-14A. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PIT - FOUND FRAME CRACKED .25 INCH, FRAME ATTACH BRACKET HOLE AT STATION 887-S9L. MANUFACTURED REPAIR IAW TYPICAL REPAIR 53-10-14A. (M)