What was found
PIT - FOUND 40 INCH BY 1 INCH AREA OF CORROSION, ZEE ANGLE AT AFT SERVICE DOOR THRESHOLD. REMOVED CORROSION, TREATED AND PRIMED PER SRM 53-60-51. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PIT - FOUND 40 INCH BY 1 INCH AREA OF CORROSION, ZEE ANGLE AT AFT SERVICE DOOR THRESHOLD. REMOVED CORROSION, TREATED AND PRIMED PER SRM 53-60-51. (M)