What was found
CLT - DURING Q-4 CHECK VISUAL INSPECTION, FOUND A .25 INCH CRACK AT STATION 727A STRINGER 5L TIE CLIP. REMOVED AND REPLACED CLIP PER EO 5393G227. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CLT - DURING Q-4 CHECK VISUAL INSPECTION, FOUND A .25 INCH CRACK AT STATION 727A STRINGER 5L TIE CLIP. REMOVED AND REPLACED CLIP PER EO 5393G227. (M)