What was found
PIT - FOUND SUPPORT CORRODED SEVERAL AREAS, BS 960 Z-ANGLE SUPPORT, AFT ENTRY THRESHOLD DOOR JAM. CORROSION, LEVEL 2, TASK NR C53-107-01. REPLACED Z-ANGLE PER BOEING DWG 65-52878. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PIT - FOUND SUPPORT CORRODED SEVERAL AREAS, BS 960 Z-ANGLE SUPPORT, AFT ENTRY THRESHOLD DOOR JAM. CORROSION, LEVEL 2, TASK NR C53-107-01. REPLACED Z-ANGLE PER BOEING DWG 65-52878. (M)