What was found
PIT - FOUND INTERCOSTAL CRACKED .5 INCH BY 7 INCH AREA, STATION 303 AND 310 AT STRINGER 4L. FABRICATED WEB, STRAP AND T-FITTING PER SRM 53-02-04. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PIT - FOUND INTERCOSTAL CRACKED .5 INCH BY 7 INCH AREA, STATION 303 AND 310 AT STRINGER 4L. FABRICATED WEB, STRAP AND T-FITTING PER SRM 53-02-04. (M)