What was found
PIT - FOUND FRAME CRACKED .125 INCH, STATION 480 STRINGER 8R AND 9R. REMOVED DAMAGED AND INSTALLED REPAIR ANGLES PER EA 74802-A. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PIT - FOUND FRAME CRACKED .125 INCH, STATION 480 STRINGER 8R AND 9R. REMOVED DAMAGED AND INSTALLED REPAIR ANGLES PER EA 74802-A. (M)