What was found
PIT - FOUND FRAME CRACKED .250 INCH, STATION 663 AND STRINGER 2L. REMOVED DAMAGED FRAME SECTION, FABRICATED AND INSTALLED REPAIR ANGLE AND FILLERS PER SRM 53-00-07, EA 75. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PIT - FOUND FRAME CRACKED .250 INCH, STATION 663 AND STRINGER 2L. REMOVED DAMAGED FRAME SECTION, FABRICATED AND INSTALLED REPAIR ANGLE AND FILLERS PER SRM 53-00-07, EA 75. (M)