What was found
TPA - FOUND FLOORBEAM CORRODED .25 INCH, FLOORBOARD ATTACH HOLE, FORWARD OF FORWARD GIRT BAR PAD. CLEANED CORRODED AREA, DIMENSIONAL CHECK PER SRM AND INSTALLED REPAIR ANGLES PER SRM 53-41-14 FIG 201. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
TPA - FOUND FLOORBEAM CORRODED .25 INCH, FLOORBOARD ATTACH HOLE, FORWARD OF FORWARD GIRT BAR PAD. CLEANED CORRODED AREA, DIMENSIONAL CHECK PER SRM AND INSTALLED REPAIR ANGLES PER SRM 53-41-14 FIG 201. (M)