What was found
PIT - FOUND SKIN CORRODED 2 INCHES BY 4 INCHES, BELOW CABIN FLOOR STATION 1016 AT BL 0 AFT PRESSURE BULKHEAD, CORROSION LEVEL 2, TASK NR C53-107-02. REMOVED CORRODED SECTION, INSTALLED DOUBLERS AND SPLICE PER SRM 53-80-08 AND 51-40-02, EA 75070. (M)