What was found
PIT - FOUND SKIN CRACKED .75 INCH LONG, SKIN AFT SERVICE DOOR LOEWR HINGE CUTOUT STATION 947.5, STRINGER 14R. DOUBLE AND TRIPLER INSTALLED AND PAINTED PER SRM 53-60-01. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PIT - FOUND SKIN CRACKED .75 INCH LONG, SKIN AFT SERVICE DOOR LOEWR HINGE CUTOUT STATION 947.5, STRINGER 14R. DOUBLE AND TRIPLER INSTALLED AND PAINTED PER SRM 53-60-01. (M)