What was found
FOUND DOOR SILL CORRODED 2 INCHES BY 6 INCHES - 2 INCHES BY 2 INCHES, Z-ANGLE, AFT SERVICE DOOR CUTOUT, STATION 951 S-17R. REMOVED CORROSION, ALODINE, PRIME PER SRM 51-10-2, 51-20-01. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FOUND DOOR SILL CORRODED 2 INCHES BY 6 INCHES - 2 INCHES BY 2 INCHES, Z-ANGLE, AFT SERVICE DOOR CUTOUT, STATION 951 S-17R. REMOVED CORROSION, ALODINE, PRIME PER SRM 51-10-2, 51-20-01. (M)