What was found
PIT - FOUND FRAME CRACKED 4 INCHES, STATION 500 BETWEEN STRINGER 26L-26R. INSTALLED TWO DOUBLERS PER SRM 51-70-11 FIG 1, DETAIL NR 2, PAGE 6. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PIT - FOUND FRAME CRACKED 4 INCHES, STATION 500 BETWEEN STRINGER 26L-26R. INSTALLED TWO DOUBLERS PER SRM 51-70-11 FIG 1, DETAIL NR 2, PAGE 6. (M)