What was found
PIT - FOUND RIGHT CREASE BEAM INNER CHORD Z-STATION 947.5 TO 986.5 PLUS 8 INCHES, WITH THREE CORRODED AREAS OF CORROSION, 3 INCHES BY 2 INCHES, 2 INCHES BY 2 INCHES, 4 INCHES BY 2 INCHES. REPLACED Z-ANGLE PER SRM 53-60-15. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PIT - FOUND RIGHT CREASE BEAM INNER CHORD Z-STATION 947.5 TO 986.5 PLUS 8 INCHES, WITH THREE CORRODED AREAS OF CORROSION, 3 INCHES BY 2 INCHES, 2 INCHES BY 2 INCHES, 4 INCHES BY 2 INCHES. REPLACED Z-ANGLE PER SRM 53-60-15. (M)