What was found
FOUND ZEE ANGLE CORRODED 2 INCHES BY 3 INCHES, AFT ENTRY DOOR ZEE ANGLE, STATION 907 TO 1006. REPLACED ZEE ANGLE PER SRM 51-10-02 AND BOEING REPAIR DWG NR 65-52878. CORROSION LEVEL 1, TASK NR C53-67-01. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FOUND ZEE ANGLE CORRODED 2 INCHES BY 3 INCHES, AFT ENTRY DOOR ZEE ANGLE, STATION 907 TO 1006. REPLACED ZEE ANGLE PER SRM 51-10-02 AND BOEING REPAIR DWG NR 65-52878. CORROSION LEVEL 1, TASK NR C53-67-01. (M)