What was found
PIT FOUND FITTING CORRODED 1 INCH LONG INSIDE RADIUS BORE, VERT STAB AFT RT OUTBOARD LUG FWD CLEVIS BETWEEN CLEVIS AND T-FITTING. REMOVED AND REPLACED BUSHING/OVERSIZE PER EA 76801. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PIT FOUND FITTING CORRODED 1 INCH LONG INSIDE RADIUS BORE, VERT STAB AFT RT OUTBOARD LUG FWD CLEVIS BETWEEN CLEVIS AND T-FITTING. REMOVED AND REPLACED BUSHING/OVERSIZE PER EA 76801. (M)