What was found
FOUND FITTING CORODED 1 INCH BETWEEN LAYERS, VERT STAB RT AFT OUTBOARD ATTACH POINT BETWEEN T-FITTING AND CLEVIS. OVERSIZED PART, REMOVED AND REPLACED BUSHING PER SRM 55-30-90 AND EA 76801. CORROSION LEVEL 1, TASK NR C55-706-11. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FOUND FITTING CORODED 1 INCH BETWEEN LAYERS, VERT STAB RT AFT OUTBOARD ATTACH POINT BETWEEN T-FITTING AND CLEVIS. OVERSIZED PART, REMOVED AND REPLACED BUSHING PER SRM 55-30-90 AND EA 76801. CORROSION LEVEL 1, TASK NR C55-706-11. (M)