What was found
FOUND FLOOR SUPPORT CORRODED 2.5 INCHES IN LENGTH, BY 1 INCH WIDE, MAX DEPTH .50 INCH, BETWEEN FRAME 14-21, RBL 48 LONGITUDINAL BEAM. DEFECTIVE PART REPLACED WITH IDENTICAL PART NR PER SRM 51-42-11. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FOUND FLOOR SUPPORT CORRODED 2.5 INCHES IN LENGTH, BY 1 INCH WIDE, MAX DEPTH .50 INCH, BETWEEN FRAME 14-21, RBL 48 LONGITUDINAL BEAM. DEFECTIVE PART REPLACED WITH IDENTICAL PART NR PER SRM 51-42-11. (M)