What was found
CLT - FOUND FLOORBEAM CORRODED 1 INCH BY 3 INCHES, FS 377.7 AND LBL 6.0 FORWARD FLANGE. INSTALLED ANGLES, BLENDED, PRIMED, PAINTED PER SRM 51-70-12, TR 53-15-02. CORROSION LEVEL 1. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CLT - FOUND FLOORBEAM CORRODED 1 INCH BY 3 INCHES, FS 377.7 AND LBL 6.0 FORWARD FLANGE. INSTALLED ANGLES, BLENDED, PRIMED, PAINTED PER SRM 51-70-12, TR 53-15-02. CORROSION LEVEL 1. (M)