What was found
FOUND SKIN CRACKED 1 INCH, EXTERNAL FUSELAGE SKIN STATION 727D PLUS 2 AT STRINGER 19R. INSTALLED DOUBLER PER SRM 53-00-01, FIG 229. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FOUND SKIN CRACKED 1 INCH, EXTERNAL FUSELAGE SKIN STATION 727D PLUS 2 AT STRINGER 19R. INSTALLED DOUBLER PER SRM 53-00-01, FIG 229. (M)