What was found
BFM - FOUND FLOORBEAM CORRODED 1 INCH IN DIAMETER BY .030 INCH DEEP, LAV E MOUNTHOLE, -Y720, 10 INCHES AFT OF FRAME 64 ON BEAM ASSEMBLY. REMOVED AND REPLACED FLOORBEAM PER SRM 53-00-14, 51-42-11. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
BFM - FOUND FLOORBEAM CORRODED 1 INCH IN DIAMETER BY .030 INCH DEEP, LAV E MOUNTHOLE, -Y720, 10 INCHES AFT OF FRAME 64 ON BEAM ASSEMBLY. REMOVED AND REPLACED FLOORBEAM PER SRM 53-00-14, 51-42-11. (M)