What was found
PIT - FOUND FLOORBEAM CORRODED 2 INCH AREA, .025 INCH DEEP, FLOORBEAM UPPER SURFACE BS 700 LBL 55. BLENDED AREA TO REMOVED CORROSION, INSTALLED REPAIR ANGLES PER EA 78224. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PIT - FOUND FLOORBEAM CORRODED 2 INCH AREA, .025 INCH DEEP, FLOORBEAM UPPER SURFACE BS 700 LBL 55. BLENDED AREA TO REMOVED CORROSION, INSTALLED REPAIR ANGLES PER EA 78224. (M)