What was found
FOUND SKIN CRACKED 2.5 INCHES, STATION 727E AT STRINGER 18R, RT FUSELAGE. INSTALLED REPAIR DOUBLER PER SRM 53-00-01. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FOUND SKIN CRACKED 2.5 INCHES, STATION 727E AT STRINGER 18R, RT FUSELAGE. INSTALLED REPAIR DOUBLER PER SRM 53-00-01. (M)