What was found
FOUND BEAM CORRODED TWO PLACES 1.5 INCH LONG BY 1 INCH WIDE BY .02 INCH DEEP, FRAME Y1292 AND CROSSBEAM C66-Z240. REMOVED AND REPLACED BEAM PER SRM 51-74-00, 53-00-14, 51-42-11. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FOUND BEAM CORRODED TWO PLACES 1.5 INCH LONG BY 1 INCH WIDE BY .02 INCH DEEP, FRAME Y1292 AND CROSSBEAM C66-Z240. REMOVED AND REPLACED BEAM PER SRM 51-74-00, 53-00-14, 51-42-11. (M)