What was found
FLOOR SUPPORT, .8 INCH X .6 INCH X .030 INCH DEEP, CORROSION; LEVEL 2; TASK NR JA-220-53500, FR 16, Y254, Z240. INSTALLED REPAIR ANGLE AND FILLER IAW SRM 51-74-00, 53-11-14, 51-21-11, 51-75-12.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FLOOR SUPPORT, .8 INCH X .6 INCH X .030 INCH DEEP, CORROSION; LEVEL 2; TASK NR JA-220-53500, FR 16, Y254, Z240. INSTALLED REPAIR ANGLE AND FILLER IAW SRM 51-74-00, 53-11-14, 51-21-11, 51-75-12.