What was found
PIT - FOUND FLOOR WEB CRACKED 1 INCH AND 1.5 INCHES, BETWEEN STATION 559 AND 578 AT STRINGER 17L. REPLACED FLOOR WEB PER SRM 51-10-2. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PIT - FOUND FLOOR WEB CRACKED 1 INCH AND 1.5 INCHES, BETWEEN STATION 559 AND 578 AT STRINGER 17L. REPLACED FLOOR WEB PER SRM 51-10-2. (M)