What was found
PIT, Q5, WEB .5000 INCH CRACK, 2ND LIGHTENING HOLE FROM FWD EDGE OF DOOR 12 INCHES UP FROM LOWER EDGE OF DOOR. CUT OUT DAMAGE AND INSTALLED REPAIR PLATE IAW SRM.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PIT, Q5, WEB .5000 INCH CRACK, 2ND LIGHTENING HOLE FROM FWD EDGE OF DOOR 12 INCHES UP FROM LOWER EDGE OF DOOR. CUT OUT DAMAGE AND INSTALLED REPAIR PLATE IAW SRM.