What was found
BFM - FOUND FLOORBEAM CORRODED 1.5 INCH BY 1 INCH BY .075 INCH AREA, FS 66-68M Y1192 TO Y1292, -Z240. REPLACED FLOORBEAM PER SRM 53-00-14. CORRODED LEVEL 2, TASK NR JA-160-53500. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
BFM - FOUND FLOORBEAM CORRODED 1.5 INCH BY 1 INCH BY .075 INCH AREA, FS 66-68M Y1192 TO Y1292, -Z240. REPLACED FLOORBEAM PER SRM 53-00-14. CORRODED LEVEL 2, TASK NR JA-160-53500. (M)