What was found
BFM - FOUND FLOOR SUPPORT CORRODED 2 INCHES BY 1.5 INCH BY .060 INCH DEEP, FRAME 68-69, Y1192, -Z240. REMOVED AND REPLACED FLOOR SUPPORT PER SRM 53-00-14. CORROSION LEVEL 2, TASK NR JA-260-535. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
BFM - FOUND FLOOR SUPPORT CORRODED 2 INCHES BY 1.5 INCH BY .060 INCH DEEP, FRAME 68-69, Y1192, -Z240. REMOVED AND REPLACED FLOOR SUPPORT PER SRM 53-00-14. CORROSION LEVEL 2, TASK NR JA-260-535. (M)