What was found
BFM - FOUND FLOOR SUPPORT FRAME CORRODED, 2 INCHES LONG BY .900 INCH WIDE BY.032 INCH DEEP, FRAME 66-68, -Y1192 TO -Y1292, -Z240. REMOVED AND REPLACED SEAT TRACK PER SRM 53-00-14. CORROSION LEVEL 2, TASK NR JA-260-5300. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
BFM - FOUND FLOOR SUPPORT FRAME CORRODED, 2 INCHES LONG BY .900 INCH WIDE BY.032 INCH DEEP, FRAME 66-68, -Y1192 TO -Y1292, -Z240. REMOVED AND REPLACED SEAT TRACK PER SRM 53-00-14. CORROSION LEVEL 2, TASK NR JA-260-5300. (M)