What was found
FLOOR SUPPORT, 2.0 INCH X 1.0 INCH X .026 INCH D, CORROSION; LEVEL 2 BETWEEN FR 21-22, Y1292, Z240. REMOVED AND REPLACED PART IAW SRM.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FLOOR SUPPORT, 2.0 INCH X 1.0 INCH X .026 INCH D, CORROSION; LEVEL 2 BETWEEN FR 21-22, Y1292, Z240. REMOVED AND REPLACED PART IAW SRM.