What was found
BFM - FOUND BEAM CORRODED 1 INCH BY .50 I NCH BY .20 INCH AREA, BETWEEN FRAME 66 AND 68 BL -Y1292. REPLACED WITH NEW PART PER SRM 53-00-10 FIG 102. CORROSION LEVEL 2, TASK NR JA-260-53500. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
BFM - FOUND BEAM CORRODED 1 INCH BY .50 I NCH BY .20 INCH AREA, BETWEEN FRAME 66 AND 68 BL -Y1292. REPLACED WITH NEW PART PER SRM 53-00-10 FIG 102. CORROSION LEVEL 2, TASK NR JA-260-53500. (M)