What was found
BFM - FOUND BEAM CORRODED 1 INCH BY 1 INCH BY .20 INCH AREA, FS 66, BL -Y1292, -Z240. REPLACED WITH NEW PART PER SRM 53-00-14 FIG 102. CORROSION LEVEL 2, TASK NR JA-260-53500. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
BFM - FOUND BEAM CORRODED 1 INCH BY 1 INCH BY .20 INCH AREA, FS 66, BL -Y1292, -Z240. REPLACED WITH NEW PART PER SRM 53-00-14 FIG 102. CORROSION LEVEL 2, TASK NR JA-260-53500. (M)