What was found
PIT FOUND WEB CRACKED 2 INCHES, STATION 1040, BL 0, 9 RIVETS UP FROM CENTER OF AFT PRESSURE DOME. CUT OUT DAMAGED AREA, INSTALLED FILLER AND DOUBLER REPAIR PER SRM 53-80-08. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PIT FOUND WEB CRACKED 2 INCHES, STATION 1040, BL 0, 9 RIVETS UP FROM CENTER OF AFT PRESSURE DOME. CUT OUT DAMAGED AREA, INSTALLED FILLER AND DOUBLER REPAIR PER SRM 53-80-08. (M)