What was found
PIT - FOUND FLOORBEAM CORRODED .5 INCH BY .100 INCH, CABIN FLOORBEAM FS 967 RBL UPPER AFT BEAM EDGE. BLENDED CORRODED AREA, TREATED AND PRIMED PER SRM 53-60-51 FIG 101 DETAIL XV. CORROSION LEVEL 1, TASK C53-107-02. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PIT - FOUND FLOORBEAM CORRODED .5 INCH BY .100 INCH, CABIN FLOORBEAM FS 967 RBL UPPER AFT BEAM EDGE. BLENDED CORRODED AREA, TREATED AND PRIMED PER SRM 53-60-51 FIG 101 DETAIL XV. CORROSION LEVEL 1, TASK C53-107-02. (M)