What was found
PIT - FOUND FLOOR SUPPORT CORRODED .5 INCH DIAMETER AT 4 SCREW HOLES UPPER EDGE FLOORBEAM FLANGE STATON 967-986.5 LBL 16. REMOVED AND REPLACED SUPPORT PER SRM 53-60-51. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PIT - FOUND FLOOR SUPPORT CORRODED .5 INCH DIAMETER AT 4 SCREW HOLES UPPER EDGE FLOORBEAM FLANGE STATON 967-986.5 LBL 16. REMOVED AND REPLACED SUPPORT PER SRM 53-60-51. (M)