What was found
PIT - FOUND FITTING CORRODED 1 INCH IN DIAMETER, TWO EACH, RSS 202 ON MAIN LANDING GEAR BEAM. REMOVED AND REPLACED FITTING, DRILLED AND REAMED AS REQUIRED PER AMM 57-15-00. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PIT - FOUND FITTING CORRODED 1 INCH IN DIAMETER, TWO EACH, RSS 202 ON MAIN LANDING GEAR BEAM. REMOVED AND REPLACED FITTING, DRILLED AND REAMED AS REQUIRED PER AMM 57-15-00. (M)