What was found
PIT - FOUND FLOOR PAN CORRODED, 4 EACH 1 INCH BY .5 INCH AREAS, SUBFLOOR AFT OF STATION 1016 TO AFT PRESSURE BULK FROM BL 0 TO RBL 37.5. REMOVED DAMAGE AND INSTALLED REPAIR ANGLE PER SRM 51-70-13. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PIT - FOUND FLOOR PAN CORRODED, 4 EACH 1 INCH BY .5 INCH AREAS, SUBFLOOR AFT OF STATION 1016 TO AFT PRESSURE BULK FROM BL 0 TO RBL 37.5. REMOVED DAMAGE AND INSTALLED REPAIR ANGLE PER SRM 51-70-13. (M)