What was found
CLT - FOUND FLOOR SUPPORT CORRODED 1.5 INCH AREA BY .020 INCH DEEP, STATION 324-318 AND OBL, FLOORBEAM. REPAIRED PER SRM 51-10-02 AND DWG 141N5191. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CLT - FOUND FLOOR SUPPORT CORRODED 1.5 INCH AREA BY .020 INCH DEEP, STATION 324-318 AND OBL, FLOORBEAM. REPAIRED PER SRM 51-10-02 AND DWG 141N5191. (M)