What was found
PIT - FOUND CLIP WITH CHAFE WEAR .75 INCH BY .1875 INCH BY .050 INCH DEEP, STATION 277 BETWEEN S2L AND S3L. REPLACED CLIP PER BOEING DWG 65-49806. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PIT - FOUND CLIP WITH CHAFE WEAR .75 INCH BY .1875 INCH BY .050 INCH DEEP, STATION 277 BETWEEN S2L AND S3L. REPLACED CLIP PER BOEING DWG 65-49806. (M)