What was found
PIT - FOUND ZEE ANGLE CORRODED TWO AREAS 1 INCH, WEB SUPPORT AT STATION 992 RBL 24. FABRICATED AND REPLACED ZEE ANGLE PER BOEING DWG PL 69-77477. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PIT - FOUND ZEE ANGLE CORRODED TWO AREAS 1 INCH, WEB SUPPORT AT STATION 992 RBL 24. FABRICATED AND REPLACED ZEE ANGLE PER BOEING DWG PL 69-77477. (M)