What was found
PIT - FOUND INTERCOSTAL CRACKED 6 PLACES, 1 INCH TO 1.5 INCH CRACKS, CENTER LINE OF FLOOR STATION 380-400, TOP OF INTERCOSTAL. FABRICATED NEW ANGLE AND INSTALLED PER SRM 51-10-02 AND BOEING DWG 69-35365. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PIT - FOUND INTERCOSTAL CRACKED 6 PLACES, 1 INCH TO 1.5 INCH CRACKS, CENTER LINE OF FLOOR STATION 380-400, TOP OF INTERCOSTAL. FABRICATED NEW ANGLE AND INSTALLED PER SRM 51-10-02 AND BOEING DWG 69-35365. (M)