What was found
PIT - FOUND STIFFENER CORRODED 1 INCH BY 1 INCH AREA, FLOOR SUPPORT BETWEEN STATION 312-328 RBL 11. REPLACED STIFFENER PER SRM 51-40-02. CORROSION LEVEL 1, TASK NR C53-107-02. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PIT - FOUND STIFFENER CORRODED 1 INCH BY 1 INCH AREA, FLOOR SUPPORT BETWEEN STATION 312-328 RBL 11. REPLACED STIFFENER PER SRM 51-40-02. CORROSION LEVEL 1, TASK NR C53-107-02. (M)