What was found
PIT - FOUND RUDDER WITH COMPOSITE DAMAGE 5.25 INCH BY 1.5 INCH SINGLE LAYER, STATION 180 PLUS 10 INCHES FROM T/E RT SIDE. REMOVED DAMAGE AND INSTALLED REPAIR PLYS PER EA 79025 AND SRM 51-70-17. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PIT - FOUND RUDDER WITH COMPOSITE DAMAGE 5.25 INCH BY 1.5 INCH SINGLE LAYER, STATION 180 PLUS 10 INCHES FROM T/E RT SIDE. REMOVED DAMAGE AND INSTALLED REPAIR PLYS PER EA 79025 AND SRM 51-70-17. (M)