What was found
CRACK IN NR 7 SLAT SUPPORT ANGLE. NR 7 SLAT LOWER T/E, 54 INCHES FROM OB END. REPLACED WITH FABRICATED ANGLE IAW SRM 51-40-02.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CRACK IN NR 7 SLAT SUPPORT ANGLE. NR 7 SLAT LOWER T/E, 54 INCHES FROM OB END. REPLACED WITH FABRICATED ANGLE IAW SRM 51-40-02.