What was found
PIT - FOUND STRINGER SPLICE CRACKED .25 INCH, STATION 908 AND STRINGER 4L. INSTALLED NEW SPLICE PER SRM 51-40-02 AND 51-40-03. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PIT - FOUND STRINGER SPLICE CRACKED .25 INCH, STATION 908 AND STRINGER 4L. INSTALLED NEW SPLICE PER SRM 51-40-02 AND 51-40-03. (M)