What was found
PIT - FOUND FRAME CRACKED .5 INCH CRACK, FRAME BS 867 S8R, S9R. CUT OUT CRACK, INSTALLED PLUG FILLER AND DOUBLER PER SRM 53-00-07. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PIT - FOUND FRAME CRACKED .5 INCH CRACK, FRAME BS 867 S8R, S9R. CUT OUT CRACK, INSTALLED PLUG FILLER AND DOUBLER PER SRM 53-00-07. (M)