What was found
PIT - FOUND FRAME CRACKED .5 INCH, FRAME BS 727F, S8L, S9L. CUT OUT CRACK, INSTALLED FILLER AND DOUBLER PER SRM 53-00-07, FIG 202. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PIT - FOUND FRAME CRACKED .5 INCH, FRAME BS 727F, S8L, S9L. CUT OUT CRACK, INSTALLED FILLER AND DOUBLER PER SRM 53-00-07, FIG 202. (M)