What was found
FLOOR SUPPORT, .5 INCH CRACK, DAMAGE AREA FLOORBEAM, STA727B, LBBL 8-10. MODIFIED REPAIR ANGLE IAW TR 53-10-06B, INSTALLED DOUBLER.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FLOOR SUPPORT, .5 INCH CRACK, DAMAGE AREA FLOORBEAM, STA727B, LBBL 8-10. MODIFIED REPAIR ANGLE IAW TR 53-10-06B, INSTALLED DOUBLER.