What was found
PIT - Q2, R-1 LUG .1250 BY .2500 INCH AREA, CORROSION; NO LEVEL OR TASK, RT HORIZ STAB R-1 LUG. CLEANED CORROSION, REMOVED AND REPLACED BUSHING, CAB PLATED IAW SRM 55-10-10, NDTM 0-4-53-10.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PIT - Q2, R-1 LUG .1250 BY .2500 INCH AREA, CORROSION; NO LEVEL OR TASK, RT HORIZ STAB R-1 LUG. CLEANED CORROSION, REMOVED AND REPLACED BUSHING, CAB PLATED IAW SRM 55-10-10, NDTM 0-4-53-10.